顶层柱纵筋(中柱):
层高-梁高-非连接区长度+锚固长度 锚固长度:梁高-砼保护层+12d
顶层柱纵筋(角柱、边柱):
层高-梁高-上层非连接区长度+顶层锚固长度
(1)纵筋
柱外侧纵筋上端锚固长度=1.5Lae =1.5×34×d=1.5×34×0.02=1.02m
柱内侧纵筋在梁内直锚长度=梁高-保护层 =0.65-0.025=0.625m<Lae=34×0.02=0.68m 柱内侧纵筋锚固长度=柱直锚长度+12d =0.625+12×0.02=0.865m
柱筋插入基础板长度=底板厚-保护层-2×直径 =0.45-0.04-2×0.018=0.374m>0.5Lae =0.5×34×0.02=0.34m
弯钩长度=12d=12×0.02=0.24>150mm ≥150
柱下端锚固长度=0.374+0.24=0.614m (2)①柱外侧纵筋长度Φ20
=基础板顶至屋面框架梁底距离+上下锚固长度 =[(2+14.4-0.45-0.65)+1.02+0.614]×6 =101.60m
②柱内侧纵筋长度Φ20
=基础板顶至屋面框架梁底距离+上下锚固长度 =[(2+14.4-0.45-0.65)+0.865+0.614]×6 =100.67m
Φ20钢筋总长=101.60+100.67=202.27m (3)箍筋φ8 单根长
=(0.45-0.03×2+0.008×2)×2×2+24×0.008 =1.82m
单根长 =[(0.45-0.03×2)/3+0.008×2)]×2+(0.45-0.03×2+0.008×2)×2+24×0.008 =1.30m
箍筋个数 加密区长度,
每层≥柱长边尺寸;≥500mm;≥Hn/6
450mm<500mm>1/6×(3.6-0.65)=492mm ∴每层加密区范围取500mm
底层加密区范围=1/3×(3.6+2-0.65-0.45)=1.5m
∴加密区长=1.5+(0.5+0.65+0.5)×3+(0.5+0.65)=7.6m 非加密区长=14.4+2-0.45-7.6=8.35m 箍筋个数=7.6/0.1+8.35/0.2+1+2 =76+42+1+2
=121个
Φ8箍筋长=(1.82+1.30)×121=377.52m (3)钢筋汇总
Φ20钢筋=202.27×2.47=499.61kg Φ8钢筋=377.52×0.395=149.12kg
相关推荐: