HPLC²â¶¨Àû¸£Åç¶¡×Ô΢ÈéÖÐÒ©ÎﺬÁ¿
Íõ¹âÄþ;º«×Ï»Ü;ÍõÑÞ
¡¾ÆÚ¿¯Ãû³Æ¡¿¡¶Ê³Æ·ÓëÒ©Æ·¡· ¡¾Äê(¾í),ÆÚ¡¿2015(000)006
¡¾ÕªÒª¡¿Objective To establish an analytic method for determination of rifapentine in self-microemulsifying drug delivery system by HPLC.Methods The Hypersil ODS C18 (4.6 mm¡Á250 mm, 5 ¦Ìm) was adopted, with methanol-0.0375 mol/L potassium dihydrogen phosphate (70:30) as mobile phase at flow rate of 1 mL/min, the detection wavelength was 254 nm and the column temperature was 25¡æ.ResultsThis method showed good linear correlation in the range of 0.008-0.08 mg/mL (R2=0.9993), and methodology study met the requirements.Conclusion The method is convenient, accurate and reproducible, which can be used for quality control of this preparation.%Ä¿µÄ£º½¨Á¢¸ßЧҺÏàÉ«Æ×·¨£¨HPLC£©²â¶¨Àû¸£Åç¶¡×Ô΢ÈéÖÐÒ©ÎﺬÁ¿¡£·½·¨É«Æ×Öù£ºHypersil ODSÖù£¨4.6 mm¡Á250 mm£¬5¦Ìm£©£»ÒÔ¼×´¼-0.0375 mol/LÁ×Ëá¶þÇâ¼ØÈÜÒº£¨70£º30£©ÎªÁ÷¶¯Ï࣬Á÷ËÙ1 mL/min£»ÖùÎÂ25¡æ£»¼ì²â²¨³¤254 nm¡£½á¹ûÀû¸£Åç¶¡ÔÚ0.008~0.08 mg/mL·¶Î§ÄÚÏßÐÔ¹ØÏµÁ¼ºÃ£¨R2=0.9993£©£¬·½·¨Ñ§¿¼²ì¾ù·ûºÏÒªÇó¡£½áÂ۸÷½·¨¼òµ¥¡¢×¼È·¡¢ÖØÏÖÐԺ㬿ÉÓÃÓÚÀû¸£Åç¶¡×Ô΢ÈéµÄÖÊÁ¿¿ØÖÆ¡£ ¡¾×ÜÒ³Êý¡¿3Ò³(435-437)
¡¾¹Ø¼ü´Ê¡¿Àû¸£Åç¶¡;×Ô΢Èé;HPLC;º¬Á¿²â¶¨