1开关柜用途标牌2自动加热除湿控制器KS-3-2SPAJ140C感湿加热指示7SD610ⅠⅡⅢ加热器故障指示ⅠⅡⅢ电源电源加热DXN-Q型户内高压带电显示装置合合镇江亨通电器有限公司分分分合闸开关分合闸开关仪表室照明开关储能开关储能灯合闸灯分闸灯310铭牌98476511121319BUSBAR14CABLE201721151816图2: KYN61-40.5 开关柜正视图 Figure2: KYN61-40.5 Front View
13
1 开关柜用途标牌
Switchgear Scutcheon
2 仪表门
Door of low-voltage compartment
3 铭牌
Nameplate
4 接地开关操作孔 Spindle
5 通风道,下部(2500A时开通风道)
ventilation grit below(2500A,with ventilation)
6 视察窗
Sight glass
7 断路器分合操作孔(断路器分合指示标牌)
Breaker ON-OFF operating advice(Breaker ON-OFF demonstrative scutcheon)
8 接地开关分合操作孔(接地开关分合指示标牌)
Earthing switch,operation mechanism(Earthing switch ON-OFF demonstrative scutcheon)
9 门锁 Lock
10 手车室门
Door of Vacuum circuit-breaker compartment
11二次小母线安装板
Control busbar installation board
12 继电器安装板
Relay installation board
13 上活门
Upside valve
14 下活门
Downside valve
15 手车接地排
Trolley earthing busbar
16 手车左导轨
Right guide rail of trolley
17 手车锁定板
Locking board of trolley
18手车右导轨
Left guide rail of trolley
19 上触头 Upside bush 20 静触头 Contact 21 下触头盒 Downside bush
14
111212341314515166717188910192021
图3: KYN61-40.5 前柜基本结构图 Figure 3: KYN61-40.5 Basic structural diagram
15
1 上活门
Upside valve
2 上隔板
Upside clapboard
3 触头盒支撑板
Bush uphold board
4 引出排(母线侧)
Derivation busbar (side of busbar)
5 上触头盒
Upside bush
6 下触头盒
Downside bush
7 引出排(电缆侧)
Derivation busbar (side of cable)
8 下隔板
Downside clapboard
9 下隔板
Downside clapboard
10 手车接地排(与主接地排相连)
Trolley earthing busbar(Linking with main earthing busbar)
11 泄压板(2500A时需强迫风冷,柜顶开通风道)
Pressure relief board(2500A with enforced cooling)
12 外壳
Shell
13 二次线通道
Control busbar passage
14 手车室门
Gate of trolly compartment
15 可移开单元
16
相关推荐: