H167 - Timed Auto Reset
To select this option you must select the Quik Call II option. This option allows you to enter the time after which the radio goes back to Quik Call decode mode (i.e., after decoding Quik Call in the Quik Call decode mode). In addition, transmitting while in the Quik Call decode mode resets the timer at the end of the transmission. The valid range is 1 - 290 seconds (a default of 5 seconds is set if this option is selected). This option will be selected automatically if option H188 is selected. If this option is not selected, the radio will be in manual reset mode: you can manually force a reset by momentarily depressing the monitor button.
H188 - Carrier Override Timed Auto Reset
To select this option you must select the Quik Call II option. This option is used in conjunction with option H167 (Timed Auto Reset). You can enter a value ranging from 1 to 290 seconds (a default of 5 seconds is set if this option is selected), in case option H167 is not already selected. If you select this option, the timer is reset at the end of the carrier. This is in addition to the characteristics described for H167. Singletones - General (PTT/RATs)
This is the most flexible option out of all the three single tone options. When selecting this option, two windows will pop-up in sequence. Enter a frequency in each of these pop-up windows. Both of these tones can be transmitted through any of the three transmit switches (PTT/RAT1/RAT2).
The valid range for these two frequencies is from 300 Hz to 3000 Hz in increments of 1 Hz. This option is a non-numbered option.This option is incompatible with the following options.
H707 - 1 Tone Singletone via PTT Button H742 - 2 Tone Singletones via RAT Buttons
The following options are enabled if you select this option: Singletone Non-Std. Pretime
Singletone Time Duration
H619 -Omit MDC Side Tones
H707 - 1 Tone Singletone via PTT Button
When selecting this option a pop-up window is displayed and you are asked to enter a frequency for single tone1. If H707 is enabled, RAT1 and RAT2 buttons are disabled and single tone1 is sent out through PTT on all channels. This option is incompatible with all the MDC Unit ID (PTT) options. The valid range for single tone1 is from 300
Hz to 3000 Hz in increments of 1 Hz. This option is incompatible with the following options:
Singletones - General (PTT/RATs)
H742 - 2 Tone Singletone via RAT Buttons. All the MDC Unit ID (PTT) Options.
The following options are enabled if you select this option : Singletone Non-Std. Pretime
Singletone Time Duration H619 -Omit MDC Side Tones
H742 - Up to 2 Singletones via RAT Buttons
This option is very similar to the Singletone - General option. When selecting this
option two pop-up windows are displayed on the screen sequentially. Enter a frequency in both the windows. If this option is enabled and none of the MDC Unit ID options are selected then signalling on PTT is disabled. If this option is selected along with any of the MDC Unit ID options then MDC Unit ID is sent out via PTT. Single tone1 is sent out through RAT1 and single tone2 is sent out through RAT2. You may leave the default single tone 2 frequency, in case you need only one single tone.This option is incompatible with the following options: Singletone - General (PTT/RATs)
H707 - 1 Tone Single tone via PTT Button Multiple Repeater Access Codes - MDC 600 Multiple Repeater Access Codes - MDC 1200
The following options are enabled if you select this option: Singletone Non-Std. Pretime Singletone Time Duration H619 -Omit MDC Side Tones