【摘要】Objective To establish the double wavelengths ratio for detecting the concentrations of reactive oxygen species( ROS) in single cell. Methods ①Adult rat cardiomyocytes were isolated by enzymatic dissociation. Fluorescence signals of the single cell were recorded by the ion imaging system for finding Lhe two excitation wavelengths which made the biggest and the smallest fluorescence signal intensities. ②Cardiomyocytes
were
perfused
with
BPS4
to
imitate
the
ischemia/reperfusion model. Some cardiomyocytes were reperfused with
GSH.
The
intracellular
ROS
concentrations
were
measured. ,Results ①The values of the fluorescence intensity at 480 nm and 420 nm were the higgest and smallest . respectively. F480/F420 was used to represenl the intracellular ROS concentrations. ②At mimic ischemia and reperfusion stages,intracellular ROS fluorescence intensities ( F480/F420) increased progressively to ( 115. 27 ±4. 52) % and ( 1 16. 99 ± 3. 99 ) % of pre-ischemia respectively. When CSH was used in reperfusion , ROS fluorescence intensity decreased quickly to ( 101. 14 ±3. 20) % of pre-ischemia. Conclusion Double wavelengths ratio could be used to detect intracellular ROS.%目的 建立双波长比例法测