TCF-GMS-8940.02

TEST REPORT IEC/IEC 60432-1 Incandesecnt lamps – Safety specifications Part 1: Tungsten halogen lamps for domestic and Similar general lighting purposes Report reference No. ........................ : TCF-GMS-8940.02 Tested by (+ signature) .................... : Kevin Yang Approved by (+ signature) ................ : King Hu ...................................................... ...................................................... Date of issue .................................. : November 22,2018 Testing laboratory ............................. : Shenzhen ZCT Technology Co.,Ltd Address ............................................ : 3/F, Building 5, Hongsheng Industrial Zone, Bao'an Road, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Applicant ........................................... : Muscat Collections & Trading Co,.Limited Address ............................................ : Rm 633 Aoyuan Building Luoxi Road Pan Yu District Guangzhou China Manufacturer .................................... : Same as applicant Address ............................................ : Standard ........................................... : IEC 60432-1:1999 +A1:2005 +A:2011 Test Report Form No. ....................... : IEC 60432-1 Master TRF ....................................... : Dated 06-06 Test procedure ................................ : CE Procedure deviation.......................... : N/A Non-standard test method ................ : N/A Type of test object ............................ : Light blub Trademark ........................................ : No Brand Model/type reference ........................ : LB-01 Rating ............................................... : 12V 35W

TRF No.: IEC 60432-1

Page 2 of 12

TCF-GMS-8940.02

Possible test case verdicts: - test case does not apply to the test object .............. : N/A - test object does meet the requirement .................... : P(ass) - test object does not meet the requirement .............. : F(ail) General remarks: \\Throughout this report a comma is used as the decimal separator. The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Determination of the test result include consideration of measurement uncertainty from the test equipment and methods. A representative sample of the product covered by this report has been tested and comply with the applicable requirements of this standard. Copy of marking plate: The marking is on the lamp neck Light Blub Brand: N/A model LB-01 12V 35W Muscat Collections & Trading Co,.Limited Rm633 Aoyuan Building Luoxi Road Pan Yu District Guangzhou China. Made in China General product information: From the test result of our inspection and test on the submitted samples, we conclude that they comply with the requirements of the standards.

TRF No.: IEC 60432-1

Page 3 of 12

TCF-GMS-8940.02

Testing Date of receipt of test item ........................................... : November 01,2018 Date (s) of performance of tests .................................. : November 01,2018 to November 22,2018 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. \\Throughout this report a point is used as the decimal separator. Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods. This test report include the following: Annex I: Photo Documentation, 1 page(s)

TRF No.: IEC 60432-1

Cl. Page 4 of 12

IEC 60432-2 / EN 60432-2 Requirement Requirements General Lamps present no danger to the user or surroundings in normal use Marking Mandatory markings Quantity tested a) mark of orgin TCF-GMS-8940.02

Remarks Verify P P P P P P N/A 2 2.1 2.2 2.2.1 200 b) the rated voltage or the rated voltage range (V) .......... : 230 c) the rated wattage (W) For lamps with 40 mm diamer light blubs or larger and with a realized wattage of 14W or less, the wattage need not be marked Rated voltage marking for lamps intended for use on United Kingdom supply voltages Marking legible and durable after the test procedure according to clause A.1 Number of the failed samples during the test.....................: Marked on the lamps Markings are legible and durable The marking is legible after rubbed by hand with a smooth cloth dampened with water for a period of 15 s The relevant symbol for dichoic rflectorized (cool beam) lamps and bowl mirror lamps Symbols for dichroic reflectorized cool beam lamps Symbols for bowl mirror lamps The appropriate symbol for operating position limitations Symbols for candel lamps Symbols for round light blub lamps A cautionary notice or suitable graphical symbol Protection against accidental contact in screw lampholders Quantity tested...................................................................: Dimension of screw capped lamp ensure the safety against accidental contact Compliance with the requirements of the relevant sheet of IEC Publication 6061-3 200 2.2.2 2.2.3 2.3 0 P P P P P P N/A N/A N/A N/A P P P

TRF No.: IEC 60432-1

Cl. Page 5 of 12

IEC 60432-2 / EN 60432-2 Requirement Number of the failed samples during the test.....................: 2.3.1 0 TCF-GMS-8940.02

Remarks Verify P P N/A N/A Lampcaps E26d ....................................... Gauge 7006-29A Lampcaps E27/25 and E27/27 ................. Gauge 7006-51A Lampcaps E27/51x39 ................................ Gauge 7006-51 E14 capped lamps Quantity test.......................................................................: 200 a) Candle lamps: E14/25x17 ...................... Gauge 7006-55 b) round light blub, pigmy, tubular and reflector lamps having neck reference diameters of 21 mm and greater: E14/25x17 .................................................. Gauge 7006-55 c) round light blub, pigmy, tubular and reflector lamps having neck reference diameters between 16 mm and 21 mm: E14/23x15 or E14/20 d) round light blub, pigmy, tubular and reflector lamps having neck reference diameters between 14 mm and 16 mm: E14/20 Number of the failed samples during the test.....................: Lamp cap temperature rise (?ts) Quantity tested...................................................................: The average of the lamp cap temperature rise values not exceeded the prescribed value Number of the failed samples during the test.....................: Batch testing Resistance to torque Caps shall remain attached during normal operations Unused lamps Quantity tested .................................................................: 200 20 0 (See Annex A) P P 0 P P P P P P N N P N P P 2.4 2.5 2.5.1 2.5.2 For unuse lamps, the lamp cap shall not move when sujected to the torque (Nm) ................................................ : 1,15 Nm for B15d caps 3,0 Nm for B22d caps 1,15 Nm for E14 caps 3,0 Nm for E27 or E27/51x39 caps Relative movement not exceed 10 degree for other than cement or adhesive No rotational movement between light blub and cap exceeding an angular displacement of 10°

TRF No.: IEC 60432-1

搜索更多关于: IEC60432-1报告模板 的文档
IEC60432-1报告模板.doc 将本文的Word文档下载到电脑,方便复制、编辑、收藏和打印
本文链接:https://www.diyifanwen.net/c6tzzk462fs862m61dk4v721et5ixw1005lo_1.html(转载请注明文章来源)
热门推荐
Copyright © 2012-2023 第一范文网 版权所有 免责声明 | 联系我们
声明 :本网站尊重并保护知识产权,根据《信息网络传播权保护条例》,如果我们转载的作品侵犯了您的权利,请在一个月内通知我们,我们会及时删除。
客服QQ:xxxxxx 邮箱:xxxxxx@qq.com
渝ICP备2023013149号
Top