3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
95.1 94.7 94.8 96.2 95.8 95.3 95.0 94.6 95.2 94.7 94.1 95.6 95.6 95.9 96.1 95.5 96.1 96.0 96.7 95.9 95.5 40.1 40.7 41.0 37.6 38.2 38.6 39.7 41.0 39.8 40.4 42.0 38.6 38.6 37.9 37.7 38.3 36.9 37.6 36.0 36.9 38.5 21.5 22.6 22.4 20.2 20.7 21.5 21.2 21.8 21.7 22.1 22.9 21.6 21.6 21.0 20.6 21.3 20.6 20.1 19.3 20.6 21.8 9
33.9 34.7 35.0 31.9 32.5 33.0 33.7 34.8 34.0 34.5 35.9 33.1 33.1 32.4 32.0 32.7 31.5 31.8 30.4 31.5 33.0 40.0 40.6 41.0 37.6 38.2 38.6 39.8 40.9 39.8 40.4 42.0 38.5 38.5 37.8 37.5 38.2 36.8 37.5 35.9 36.9 38.4 6.2 12.3 92.3 5.9 12.1 92.3 6.0 12.5 92.1 5.7 11.6 93.5 5.7 11.7 93.1 5.6 11.5 93.1 6.0 12.5 95.0 6.2 12.9 92.0 5.8 12.2 92.4 5.8 12.4 92.4 6.1 13.0 91.8 5.5 11.4 93.0 5.5 11.4 93.0 5.5 11.3 93.2 5.6 11.4 93.4 5.6 11.3 92.5 5.4 10.8 93.5 5.8 11.7 93.4 5.5 11.1 94.1 5.4 10.9 93.4 5.4 11.2 92.9 3000 3000 94.6 95.5 40.5 38.5 22.7 21.0 34.6 32.7 40.4 38.4 5.8 11.9 92.0 5.9 11.5 93.1 改造后参数表 排气温循环进循环出凝汽温端差 温升 真空度 度 水 水 度 (kW) (-kPa) oC oC % C 温度oC ooC 温度oC 3000 94.3 37.4 23.5 34.3 38.3 3.1 10.7 95.8 真空 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
最高负荷 93.5 93.3 93.2 94.4 94.7 93.8 93.7 94.8 92.7 94.2 94.9 94.0 93.5 93.2 93.0 93.5 94.0 93.3 92.9 92.0 91.2 92.1 93.5 93.5 92.7 38.7 39.0 38.5 35.8 35.5 38.0 38.9 37.1 41.1 38.4 36.4 38.0 38.6 38.3 38.7 38.0 38.3 38.7 39.4 41.1 42.2 40.1 37.8 38.1 39.5 25.2 25.1 24.6 22.8 22.7 24.9 25.6 23.3 26.1 24.1 23.7 24.6 25.1 25.0 25.6 25.1 23.5 25.4 27.2 27.9 28.9 27.7 26.7 26.9 27.8 10
35.7 36.1 35.6 32.5 32.3 34.9 36.1 33.7 38.3 35.3 33.1 35.0 35.5 35.2 35.6 34.9 35.4 35.5 36.7 38.3 39.3 36.8 34.5 34.8 36.4 39.5 39.9 39.3 36.8 36.4 38.8 39.8 37.9 42.0 39.2 37.2 38.8 39.4 39.1 39.5 38.8 39.3 39.5 38.8 37.0 43.0 40.9 38.6 38.9 40.4 3.0 10.4 92.8 2.9 11.0 92.7 2.8 11.0 92.6 3.3 9.6 93.8 94.0 3.0 10.0 93.1 2.8 10.4 93.0 3.3 10.4 93.9 3.2 9.5 2.8 12.1 92.5 3.0 11.2 93.1 93.7 2.9 10.4 93.8 3.1 10.3 93.4 3.1 10.1 93.0 3.2 9.4 3.0 10.0 92.8 3.1 9.7 93.3 2.9 11.9 93.4 3.2 10.0 93.1 92.7 2.8 10.3 91.8 2.8 10.3 91.1 3.2 9.1 91.9 2.7 9.5 3.3 3.3 3.0 7.8 7.9 8.6 93.3 93.3 92.5 3000 3000 3000 3000 3000 92.6 93.3 93.1 93.0 93.4 40.4 39.2 40.0 39.6 38.6 28.0 27.4 27.1 26.5 25.5 37.4 36.0 37.0 36.4 35.5 41.2 40.0 40.9 40.4 39.2 2.9 3.1 3.0 3.2 9.4 8.6 9.8 9.8 92.5 93.1 92.9 92.8 3.0 10.0 93.1 从以上工况对比得出,改造后传热端差降低3℃左右,传热效果大大提高。
七、节煤效益
用不锈钢光管改造前后对比:根据实际运行参数,改造后凝汽器传热端差下降3℃左右,每年可节约原煤8万吨÷390×3÷0.8=769吨,按每吨原煤300元计算,每年可节约燃煤费用23万元。
长期使用过程中铜管清洁度明显比不锈钢波光差,特别是夏季,管内壁微生物及结垢都比较严重,因此随着使用时间的延长,在换热效果上不锈钢管更具优势。
八、结论
综合效益对比表 单位:万元 序号 效益 指标 凝汽器铜管 76 凝汽器不锈钢管 29.3 节省 金额 30年寿命期内 效益计算 1 一次投资 每年燃煤2 (煤价300元/吨) 46.7(当年) 46.7+76×2=199 2400 2377 23(当年) 23×30=690 3 临检费用 70/年
10/年 11
46(当年) 46×30=1380 4 当年费用 2546 5 使用寿命 10年 2430 30年 116(当年) 2269(30年) 199+690+1380=2269 其中:临检费用分析表
序号 项目 凝汽器 铜管 1 临检次数 12 凝汽器不锈钢管 4 4次×2.4/19(当年) 汽、电损失 启、停机、临检3 加班费 12次×12万度/12次×1/次=12 节省金额 启、停机煤、水、12次×2.4/次2 =29 次=10 4次×1/次8(当年) =4 4次×12万度/次×4 停机买电 次×0.2元/度0.2元/度=29 =9.6 5 年临检费用 70 24 19(当年) 46 通过热电厂凝汽器采用不锈钢光管直接换管的使用效果可知:在同等换热面积和运行工况下,不锈钢光管比铜管具有换热效果好、使用寿命长、长期运行管壁清洁度高,维修费用低等显著优点,因此,无论是在新建机组还是老厂改造,都极具推广价值。