FAA01, FAA08
General Specifications
Function and Time Setting
Upper right knob:Setting of functionA-delay on operateB2-simmetrical recyclerE-intervalJ-one shotLower right knob:Time unit selectorsec(seconds)min(minuts)hrs(hours)10h(10 hours)
Lower left knob:Time range selector1.2, 3, 12and 30Centre knob:
Time setting on relative scale
Mode of Operation
Function A
Delay on operate
The set delay period beginsas soon as the power supplyis connected. At the end ofthe set delay the relay oper-ates and doesn’t releaseuntil the power supply isinterrupted for at least 100ms.
Function B2
Symmetrical recycler(ON first)
The relay operates and thetime period start as soon asthe power is applied. At theend of the first set time peri-od, the relay releases. At theend of the second time peri-od (equal to the first), therelay operates again. Thissequence continues withequal ON- and OFF- timeperiods until the power sup-ply is interrupted for at least100 ms.
Function EInterval
The relay operates and thetime period begins as soonas the power is applied. Therelay releases at the end ofthe time period or when thepower supply is disconnect-ed for at least 100 ms.
Function JOne shot
The time period begins assoon as the power supply isconnected and at the end ofthis period the relay operatesfor 1s.
Range and operation mode selection
2
Specifications are subject to change without notice (26.07.05)
搜索“diyifanwen.net”或“第一范文网”即可找到本站免费阅读全部范文。收藏本站方便下次阅读,第一范文网,提供最新高中教育FAA01DM24中文资料(2)全文阅读和word下载服务。
相关推荐: