IST8310 Datasheet, Version 1.2
8
3 Operational Modes and Functional Descriptions
3.1 Operation modes
IST8310 has following operation modes:
(1) Stand-By Mode
(2) Single Measurement Mode
(3) Self-Test Mode
3.1.1 Stand-By Mode
The initial mode (after power on) of IST8310 is Stand-By Mode. In Stand-By Mode, all internal circuits are off (except oscillator and regulator). All registers can be accessed in Stand-By Mode. Data stored in Read/Write registers remains as last state. Registers can be reset by soft reset or hard reset (through RSTN pin).