5.3 Ultra-low Hysteresis Design
iSentek has developed a specialized high permeability (μ) material for magnetic field detection. This high-μ material has ultra-low residual magnetization below 0.1 %FS in the field range as large as +/- 500 G. The ultra-low hysteresis design prevents the magnetometer from dynamic offset after encountering a strong external magnetic field impact; that is, the angular accuracy restores automatically without calibration after the removal of interference field. This feature fulfills the requirements for applications when real time calibration is not available. No calibration is required in general conditions.
5.4 Magnetic Setting Mechanism
AMR sensing resistors consist of Permalloy thin film and metallization. Permalloy is soft magnetic, irreversible magnetic rotation may occur after the strength of external magnetic field exceeds half of the anisotropy field of the sensing resistor, resulting in angular error induced by offset. To solve this issue, a magnetic setting mechanism is introduced in IST8310. A magnetic field is generated within IST8310 to align the magnetization of AMR sensing resistors before every measurement. This auto-zeroing mechanism ensures the stability of angular accuracy of IST8310 during whole operation.